]> asedeno.scripts.mit.edu Git - linux.git/blob - drivers/acpi/processor_thermal.c
Linux 5.6-rc7
[linux.git] / drivers / acpi / processor_thermal.c
1 // SPDX-License-Identifier: GPL-2.0-or-later
2 /*
3  * processor_thermal.c - Passive cooling submodule of the ACPI processor driver
4  *
5  *  Copyright (C) 2001, 2002 Andy Grover <andrew.grover@intel.com>
6  *  Copyright (C) 2001, 2002 Paul Diefenbaugh <paul.s.diefenbaugh@intel.com>
7  *  Copyright (C) 2004       Dominik Brodowski <linux@brodo.de>
8  *  Copyright (C) 2004  Anil S Keshavamurthy <anil.s.keshavamurthy@intel.com>
9  *                      - Added processor hotplug support
10  */
11
12 #include <linux/kernel.h>
13 #include <linux/module.h>
14 #include <linux/init.h>
15 #include <linux/cpufreq.h>
16 #include <linux/acpi.h>
17 #include <acpi/processor.h>
18 #include <linux/uaccess.h>
19
20 #define PREFIX "ACPI: "
21
22 #define ACPI_PROCESSOR_CLASS            "processor"
23 #define _COMPONENT              ACPI_PROCESSOR_COMPONENT
24 ACPI_MODULE_NAME("processor_thermal");
25
26 #ifdef CONFIG_CPU_FREQ
27
28 /* If a passive cooling situation is detected, primarily CPUfreq is used, as it
29  * offers (in most cases) voltage scaling in addition to frequency scaling, and
30  * thus a cubic (instead of linear) reduction of energy. Also, we allow for
31  * _any_ cpufreq driver and not only the acpi-cpufreq driver.
32  */
33
34 #define CPUFREQ_THERMAL_MIN_STEP 0
35 #define CPUFREQ_THERMAL_MAX_STEP 3
36
37 static DEFINE_PER_CPU(unsigned int, cpufreq_thermal_reduction_pctg);
38
39 #define reduction_pctg(cpu) \
40         per_cpu(cpufreq_thermal_reduction_pctg, phys_package_first_cpu(cpu))
41
42 /*
43  * Emulate "per package data" using per cpu data (which should really be
44  * provided elsewhere)
45  *
46  * Note we can lose a CPU on cpu hotunplug, in this case we forget the state
47  * temporarily. Fortunately that's not a big issue here (I hope)
48  */
49 static int phys_package_first_cpu(int cpu)
50 {
51         int i;
52         int id = topology_physical_package_id(cpu);
53
54         for_each_online_cpu(i)
55                 if (topology_physical_package_id(i) == id)
56                         return i;
57         return 0;
58 }
59
60 static int cpu_has_cpufreq(unsigned int cpu)
61 {
62         struct cpufreq_policy policy;
63         if (!acpi_processor_cpufreq_init || cpufreq_get_policy(&policy, cpu))
64                 return 0;
65         return 1;
66 }
67
68 static int cpufreq_get_max_state(unsigned int cpu)
69 {
70         if (!cpu_has_cpufreq(cpu))
71                 return 0;
72
73         return CPUFREQ_THERMAL_MAX_STEP;
74 }
75
76 static int cpufreq_get_cur_state(unsigned int cpu)
77 {
78         if (!cpu_has_cpufreq(cpu))
79                 return 0;
80
81         return reduction_pctg(cpu);
82 }
83
84 static int cpufreq_set_cur_state(unsigned int cpu, int state)
85 {
86         struct cpufreq_policy *policy;
87         struct acpi_processor *pr;
88         unsigned long max_freq;
89         int i, ret;
90
91         if (!cpu_has_cpufreq(cpu))
92                 return 0;
93
94         reduction_pctg(cpu) = state;
95
96         /*
97          * Update all the CPUs in the same package because they all
98          * contribute to the temperature and often share the same
99          * frequency.
100          */
101         for_each_online_cpu(i) {
102                 if (topology_physical_package_id(i) !=
103                     topology_physical_package_id(cpu))
104                         continue;
105
106                 pr = per_cpu(processors, i);
107
108                 if (unlikely(!freq_qos_request_active(&pr->thermal_req)))
109                         continue;
110
111                 policy = cpufreq_cpu_get(i);
112                 if (!policy)
113                         return -EINVAL;
114
115                 max_freq = (policy->cpuinfo.max_freq * (100 - reduction_pctg(i) * 20)) / 100;
116
117                 cpufreq_cpu_put(policy);
118
119                 ret = freq_qos_update_request(&pr->thermal_req, max_freq);
120                 if (ret < 0) {
121                         pr_warn("Failed to update thermal freq constraint: CPU%d (%d)\n",
122                                 pr->id, ret);
123                 }
124         }
125         return 0;
126 }
127
128 void acpi_thermal_cpufreq_init(struct cpufreq_policy *policy)
129 {
130         unsigned int cpu;
131
132         for_each_cpu(cpu, policy->related_cpus) {
133                 struct acpi_processor *pr = per_cpu(processors, cpu);
134                 int ret;
135
136                 if (!pr)
137                         continue;
138
139                 ret = freq_qos_add_request(&policy->constraints,
140                                            &pr->thermal_req,
141                                            FREQ_QOS_MAX, INT_MAX);
142                 if (ret < 0)
143                         pr_err("Failed to add freq constraint for CPU%d (%d)\n",
144                                cpu, ret);
145         }
146 }
147
148 void acpi_thermal_cpufreq_exit(struct cpufreq_policy *policy)
149 {
150         unsigned int cpu;
151
152         for_each_cpu(cpu, policy->related_cpus) {
153                 struct acpi_processor *pr = per_cpu(processors, policy->cpu);
154
155                 if (pr)
156                         freq_qos_remove_request(&pr->thermal_req);
157         }
158 }
159 #else                           /* ! CONFIG_CPU_FREQ */
160 static int cpufreq_get_max_state(unsigned int cpu)
161 {
162         return 0;
163 }
164
165 static int cpufreq_get_cur_state(unsigned int cpu)
166 {
167         return 0;
168 }
169
170 static int cpufreq_set_cur_state(unsigned int cpu, int state)
171 {
172         return 0;
173 }
174
175 #endif
176
177 /* thermal cooling device callbacks */
178 static int acpi_processor_max_state(struct acpi_processor *pr)
179 {
180         int max_state = 0;
181
182         /*
183          * There exists four states according to
184          * cpufreq_thermal_reduction_pctg. 0, 1, 2, 3
185          */
186         max_state += cpufreq_get_max_state(pr->id);
187         if (pr->flags.throttling)
188                 max_state += (pr->throttling.state_count -1);
189
190         return max_state;
191 }
192 static int
193 processor_get_max_state(struct thermal_cooling_device *cdev,
194                         unsigned long *state)
195 {
196         struct acpi_device *device = cdev->devdata;
197         struct acpi_processor *pr;
198
199         if (!device)
200                 return -EINVAL;
201
202         pr = acpi_driver_data(device);
203         if (!pr)
204                 return -EINVAL;
205
206         *state = acpi_processor_max_state(pr);
207         return 0;
208 }
209
210 static int
211 processor_get_cur_state(struct thermal_cooling_device *cdev,
212                         unsigned long *cur_state)
213 {
214         struct acpi_device *device = cdev->devdata;
215         struct acpi_processor *pr;
216
217         if (!device)
218                 return -EINVAL;
219
220         pr = acpi_driver_data(device);
221         if (!pr)
222                 return -EINVAL;
223
224         *cur_state = cpufreq_get_cur_state(pr->id);
225         if (pr->flags.throttling)
226                 *cur_state += pr->throttling.state;
227         return 0;
228 }
229
230 static int
231 processor_set_cur_state(struct thermal_cooling_device *cdev,
232                         unsigned long state)
233 {
234         struct acpi_device *device = cdev->devdata;
235         struct acpi_processor *pr;
236         int result = 0;
237         int max_pstate;
238
239         if (!device)
240                 return -EINVAL;
241
242         pr = acpi_driver_data(device);
243         if (!pr)
244                 return -EINVAL;
245
246         max_pstate = cpufreq_get_max_state(pr->id);
247
248         if (state > acpi_processor_max_state(pr))
249                 return -EINVAL;
250
251         if (state <= max_pstate) {
252                 if (pr->flags.throttling && pr->throttling.state)
253                         result = acpi_processor_set_throttling(pr, 0, false);
254                 cpufreq_set_cur_state(pr->id, state);
255         } else {
256                 cpufreq_set_cur_state(pr->id, max_pstate);
257                 result = acpi_processor_set_throttling(pr,
258                                 state - max_pstate, false);
259         }
260         return result;
261 }
262
263 const struct thermal_cooling_device_ops processor_cooling_ops = {
264         .get_max_state = processor_get_max_state,