]> asedeno.scripts.mit.edu Git - linux.git/blob - drivers/net/Kconfig
Merge git://git.kernel.org/pub/scm/linux/kernel/git/davem/net
[linux.git] / drivers / net / Kconfig
1 #
2 # Network device configuration
3 #
4
5 menuconfig NETDEVICES
6         default y if UML
7         depends on NET
8         bool "Network device support"
9         ---help---
10           You can say N here if you don't intend to connect your Linux box to
11           any other computer at all.
12
13           You'll have to say Y if your computer contains a network card that
14           you want to use under Linux. If you are going to run SLIP or PPP over
15           telephone line or null modem cable you need say Y here. Connecting
16           two machines with parallel ports using PLIP needs this, as well as
17           AX.25/KISS for sending Internet traffic over amateur radio links.
18
19           See also "The Linux Network Administrator's Guide" by Olaf Kirch and
20           Terry Dawson. Available at <http://www.tldp.org/guides.html>.
21
22           If unsure, say Y.
23
24 # All the following symbols are dependent on NETDEVICES - do not repeat
25 # that for each of the symbols.
26 if NETDEVICES
27
28 config MII
29         tristate
30
31 config NET_CORE
32         default y
33         bool "Network core driver support"
34         ---help---
35           You can say N here if you do not intend to use any of the
36           networking core drivers (i.e. VLAN, bridging, bonding, etc.)
37
38 if NET_CORE
39
40 config BONDING
41         tristate "Bonding driver support"
42         depends on INET
43         depends on IPV6 || IPV6=n
44         ---help---
45           Say 'Y' or 'M' if you wish to be able to 'bond' multiple Ethernet
46           Channels together. This is called 'Etherchannel' by Cisco,
47           'Trunking' by Sun, 802.3ad by the IEEE, and 'Bonding' in Linux.
48
49           The driver supports multiple bonding modes to allow for both high
50           performance and high availability operation.
51
52           Refer to <file:Documentation/networking/bonding.txt> for more
53           information.
54
55           To compile this driver as a module, choose M here: the module
56           will be called bonding.
57
58 config DUMMY
59         tristate "Dummy net driver support"
60         ---help---
61           This is essentially a bit-bucket device (i.e. traffic you send to
62           this device is consigned into oblivion) with a configurable IP
63           address. It is most commonly used in order to make your currently
64           inactive SLIP address seem like a real address for local programs.
65           If you use SLIP or PPP, you might want to say Y here. It won't
66           enlarge your kernel. What a deal. Read about it in the Network
67           Administrator's Guide, available from
68           <http://www.tldp.org/docs.html#guide>.
69
70           To compile this driver as a module, choose M here: the module
71           will be called dummy.
72
73 config EQUALIZER
74         tristate "EQL (serial line load balancing) support"
75         ---help---
76           If you have two serial connections to some other computer (this
77           usually requires two modems and two telephone lines) and you use
78           SLIP (the protocol for sending Internet traffic over telephone
79           lines) or PPP (a better SLIP) on them, you can make them behave like
80           one double speed connection using this driver.  Naturally, this has
81           to be supported at the other end as well, either with a similar EQL
82           Linux driver or with a Livingston Portmaster 2e.
83
84           Say Y if you want this and read
85           <file:Documentation/networking/eql.txt>.  You may also want to read
86           section 6.2 of the NET-3-HOWTO, available from
87           <http://www.tldp.org/docs.html#howto>.
88
89           To compile this driver as a module, choose M here: the module
90           will be called eql.  If unsure, say N.
91
92 config NET_FC
93         bool "Fibre Channel driver support"
94         depends on SCSI && PCI
95         help
96           Fibre Channel is a high speed serial protocol mainly used to connect
97           large storage devices to the computer; it is compatible with and
98           intended to replace SCSI.
99
100           If you intend to use Fibre Channel, you need to have a Fibre channel
101           adaptor card in your computer; say Y here and to the driver for your
102           adaptor below. You also should have said Y to "SCSI support" and
103           "SCSI generic support".
104
105 config IFB
106         tristate "Intermediate Functional Block support"
107         depends on NET_CLS_ACT
108         ---help---
109           This is an intermediate driver that allows sharing of
110           resources.
111           To compile this driver as a module, choose M here: the module
112           will be called ifb.  If you want to use more than one ifb
113           device at a time, you need to compile this driver as a module.
114           Instead of 'ifb', the devices will then be called 'ifb0',
115           'ifb1' etc.
116           Look at the iproute2 documentation directory for usage etc
117
118 source "drivers/net/team/Kconfig"
119
120 config MACVLAN
121         tristate "MAC-VLAN support"
122         ---help---
123           This allows one to create virtual interfaces that map packets to
124           or from specific MAC addresses to a particular interface.
125
126           Macvlan devices can be added using the "ip" command from the
127           iproute2 package starting with the iproute2-2.6.23 release:
128
129           "ip link add link <real dev> [ address MAC ] [ NAME ] type macvlan"
130
131           To compile this driver as a module, choose M here: the module
132           will be called macvlan.
133
134 config MACVTAP
135         tristate "MAC-VLAN based tap driver"
136         depends on MACVLAN
137         depends on INET
138         select TAP
139         help
140           This adds a specialized tap character device driver that is based
141           on the MAC-VLAN network interface, called macvtap. A macvtap device
142           can be added in the same way as a macvlan device, using 'type
143           macvtap', and then be accessed through the tap user space interface.
144
145           To compile this driver as a module, choose M here: the module
146           will be called macvtap.
147
148
149 config IPVLAN
150     tristate "IP-VLAN support"
151     depends on INET
152     depends on IPV6 || !IPV6
153     depends on NETFILTER
154     select NET_L3_MASTER_DEV
155     ---help---
156       This allows one to create virtual devices off of a main interface
157       and packets will be delivered based on the dest L3 (IPv6/IPv4 addr)
158       on packets. All interfaces (including the main interface) share L2
159       making it transparent to the connected L2 switch.
160
161       Ipvlan devices can be added using the "ip" command from the
162       iproute2 package starting with the iproute2-3.19 release:
163
164       "ip link add link <main-dev> [ NAME ] type ipvlan"
165
166       To compile this driver as a module, choose M here: the module
167       will be called ipvlan.
168
169 config IPVTAP
170         tristate "IP-VLAN based tap driver"
171         depends on IPVLAN
172         depends on INET
173         select TAP
174         ---help---
175           This adds a specialized tap character device driver that is based
176           on the IP-VLAN network interface, called ipvtap. An ipvtap device
177           can be added in the same way as a ipvlan device, using 'type
178           ipvtap', and then be accessed through the tap user space interface.
179
180           To compile this driver as a module, choose M here: the module
181           will be called ipvtap.
182
183 config VXLAN
184        tristate "Virtual eXtensible Local Area Network (VXLAN)"
185        depends on INET
186        select NET_UDP_TUNNEL
187        select GRO_CELLS
188        ---help---
189           This allows one to create vxlan virtual interfaces that provide
190           Layer 2 Networks over Layer 3 Networks. VXLAN is often used
191           to tunnel virtual network infrastructure in virtualized environments.
192           For more information see:
193             http://tools.ietf.org/html/draft-mahalingam-dutt-dcops-vxlan-02
194
195           To compile this driver as a module, choose M here: the module
196           will be called vxlan.
197
198 config GENEVE
199        tristate "Generic Network Virtualization Encapsulation"
200        depends on INET && NET_UDP_TUNNEL
201        depends on IPV6 || !IPV6
202        select NET_IP_TUNNEL
203        select GRO_CELLS
204        ---help---
205           This allows one to create geneve virtual interfaces that provide
206           Layer 2 Networks over Layer 3 Networks. GENEVE is often used
207           to tunnel virtual network infrastructure in virtualized environments.
208           For more information see:
209             http://tools.ietf.org/html/draft-gross-geneve-02
210
211           To compile this driver as a module, choose M here: the module
212           will be called geneve.
213
214 config GTP
215         tristate "GPRS Tunneling Protocol datapath (GTP-U)"
216         depends on INET && NET_UDP_TUNNEL
217         select NET_IP_TUNNEL
218         ---help---
219           This allows one to create gtp virtual interfaces that provide
220           the GPRS Tunneling Protocol datapath (GTP-U). This tunneling protocol
221           is used to prevent subscribers from accessing mobile carrier core
222           network infrastructure. This driver requires a userspace software that
223           implements the signaling protocol (GTP-C) to update its PDP context
224           base, such as OpenGGSN <http://git.osmocom.org/openggsn/). This
225           tunneling protocol is implemented according to the GSM TS 09.60 and
226           3GPP TS 29.060 standards.
227
228           To compile this drivers as a module, choose M here: the module
229           wil be called gtp.
230
231 config MACSEC
232         tristate "IEEE 802.1AE MAC-level encryption (MACsec)"
233         select CRYPTO
234         select CRYPTO_AES
235         select CRYPTO_GCM
236         select GRO_CELLS
237         ---help---
238            MACsec is an encryption standard for Ethernet.
239
240 config NETCONSOLE
241         tristate "Network console logging support"
242         ---help---
243         If you want to log kernel messages over the network, enable this.
244         See <file:Documentation/networking/netconsole.txt> for details.
245
246 config NETCONSOLE_DYNAMIC
247         bool "Dynamic reconfiguration of logging targets"
248         depends on NETCONSOLE && SYSFS && CONFIGFS_FS && \
249                         !(NETCONSOLE=y && CONFIGFS_FS=m)
250         help
251           This option enables the ability to dynamically reconfigure target
252           parameters (interface, IP addresses, port numbers, MAC addresses)
253           at runtime through a userspace interface exported using configfs.
254           See <file:Documentation/networking/netconsole.txt> for details.
255
256 config NETPOLL
257         def_bool NETCONSOLE
258         select SRCU
259
260 config NET_POLL_CONTROLLER
261         def_bool NETPOLL
262
263 config NTB_NETDEV
264         tristate "Virtual Ethernet over NTB Transport"
265         depends on NTB_TRANSPORT
266
267 config RIONET
268         tristate "RapidIO Ethernet over messaging driver support"
269         depends on RAPIDIO
270
271 config RIONET_TX_SIZE
272         int "Number of outbound queue entries"
273         depends on RIONET
274         default "128"
275
276 config RIONET_RX_SIZE
277         int "Number of inbound queue entries"
278         depends on RIONET
279         default "128"
280
281 config TUN
282         tristate "Universal TUN/TAP device driver support"
283         depends on INET
284         select CRC32
285         ---help---
286           TUN/TAP provides packet reception and transmission for user space
287           programs.  It can be viewed as a simple Point-to-Point or Ethernet
288           device, which instead of receiving packets from a physical media,
289           receives them from user space program and instead of sending packets
290           via physical media writes them to the user space program.
291
292           When a program opens /dev/net/tun, driver creates and registers
293           corresponding net device tunX or tapX.  After a program closed above
294           devices, driver will automatically delete tunXX or tapXX device and
295           all routes corresponding to it.
296
297           Please read <file:Documentation/networking/tuntap.txt> for more
298           information.
299
300           To compile this driver as a module, choose M here: the module
301           will be called tun.
302
303           If you don't know what to use this for, you don't need it.
304
305 config TAP
306         tristate
307         ---help---
308           This option is selected by any driver implementing tap user space
309           interface for a virtual interface to re-use core tap functionality.
310
311 config TUN_VNET_CROSS_LE
312         bool "Support for cross-endian vnet headers on little-endian kernels"
313         default n
314         ---help---
315           This option allows TUN/TAP and MACVTAP device drivers in a
316           little-endian kernel to parse vnet headers that come from a
317           big-endian legacy virtio device.
318
319           Userspace programs can control the feature using the TUNSETVNETBE
320           and TUNGETVNETBE ioctls.
321
322           Unless you have a little-endian system hosting a big-endian virtual
323           machine with a legacy virtio NIC, you should say N.
324
325 config VETH
326         tristate "Virtual ethernet pair device"
327         ---help---
328           This device is a local ethernet tunnel. Devices are created in pairs.
329           When one end receives the packet it appears on its pair and vice
330           versa.
331
332 config VIRTIO_NET
333         tristate "Virtio network driver"
334         depends on VIRTIO
335         ---help---
336           This is the virtual network driver for virtio.  It can be used with
337           QEMU based VMMs (like KVM or Xen).  Say Y or M.
338
339 config NLMON
340         tristate "Virtual netlink monitoring device"
341         ---help---
342           This option enables a monitoring net device for netlink skbs. The
343           purpose of this is to analyze netlink messages with packet sockets.
344           Thus applications like tcpdump will be able to see local netlink
345           messages if they tap into the netlink device, record pcaps for further
346           diagnostics, etc. This is mostly intended for developers or support
347           to debug netlink issues. If unsure, say N.
348
349 config NET_VRF
350         tristate "Virtual Routing and Forwarding (Lite)"
351         depends on IP_MULTIPLE_TABLES
352         depends on NET_L3_MASTER_DEV
353         depends on IPV6 || IPV6=n
354         depends on IPV6_MULTIPLE_TABLES || IPV6=n
355         ---help---
356           This option enables the support for mapping interfaces into VRF's. The
357           support enables VRF devices.
358
359 config VSOCKMON
360     tristate "Virtual vsock monitoring device"
361     depends on VHOST_VSOCK
362     ---help---
363      This option enables a monitoring net device for vsock sockets. It is
364      mostly intended for developers or support to debug vsock issues. If
365      unsure, say N.
366
367 endif # NET_CORE
368
369 config SUNGEM_PHY
370         tristate
371
372 source "drivers/net/arcnet/Kconfig"
373
374 source "drivers/atm/Kconfig"
375
376 source "drivers/net/caif/Kconfig"
377
378 source "drivers/net/dsa/Kconfig"
379
380 source "drivers/net/ethernet/Kconfig"
381
382 source "drivers/net/fddi/Kconfig"
383
384 source "drivers/net/hippi/Kconfig"
385
386 config NET_SB1000
387         tristate "General Instruments Surfboard 1000"
388         depends on PNP
389         ---help---
390           This is a driver for the General Instrument (also known as
391           NextLevel) SURFboard 1000 internal
392           cable modem. This is an ISA card which is used by a number of cable
393           TV companies to provide cable modem access. It's a one-way
394           downstream-only cable modem, meaning that your upstream net link is
395           provided by your regular phone modem.
396
397           At present this driver only compiles as a module, so say M here if
398           you have this card. The module will be called sb1000. Then read
399           <file:Documentation/networking/README.sb1000> for information on how
400           to use this module, as it needs special ppp scripts for establishing
401           a connection. Further documentation and the necessary scripts can be
402           found at:
403
404           <http://www.jacksonville.net/~fventuri/>
405           <http://home.adelphia.net/~siglercm/sb1000.html>
406           <http://linuxpower.cx/~cable/>
407
408           If you don't have this card, of course say N.
409
410 source "drivers/net/phy/Kconfig"
411
412 source "drivers/net/plip/Kconfig"
413
414 source "drivers/net/ppp/Kconfig"
415
416 source "drivers/net/slip/Kconfig"
417
418 source "drivers/s390/net/Kconfig"
419
420 source "drivers/net/usb/Kconfig"
421
422 source "drivers/net/wireless/Kconfig"
423
424 source "drivers/net/wimax/Kconfig"
425
426 source "drivers/net/wan/Kconfig"
427
428 source "drivers/net/ieee802154/Kconfig"
429
430 config XEN_NETDEV_FRONTEND
431         tristate "Xen network device frontend driver"
432         depends on XEN
433         select XEN_XENBUS_FRONTEND
434         default y
435         help
436           This driver provides support for Xen paravirtual network
437           devices exported by a Xen network driver domain (often
438           domain 0).
439
440           The corresponding Linux backend driver is enabled by the
441           CONFIG_XEN_NETDEV_BACKEND option.
442
443           If you are compiling a kernel for use as Xen guest, you
444           should say Y here. To compile this driver as a module, chose
445           M here: the module will be called xen-netfront.
446
447 config XEN_NETDEV_BACKEND
448         tristate "Xen backend network device"
449         depends on XEN_BACKEND
450         help
451           This driver allows the kernel to act as a Xen network driver
452           domain which exports paravirtual network devices to other
453           Xen domains. These devices can be accessed by any operating
454           system that implements a compatible front end.
455
456           The corresponding Linux frontend driver is enabled by the
457           CONFIG_XEN_NETDEV_FRONTEND configuration option.
458
459           The backend driver presents a standard network device
460           endpoint for each paravirtual network device to the driver
461           domain network stack. These can then be bridged or routed
462           etc in order to provide full network connectivity.
463
464           If you are compiling a kernel to run in a Xen network driver
465           domain (often this is domain 0) you should say Y here. To
466           compile this driver as a module, chose M here: the module
467           will be called xen-netback.
468
469 config VMXNET3
470         tristate "VMware VMXNET3 ethernet driver"
471         depends on PCI && INET
472         depends on !(PAGE_SIZE_64KB || ARM64_64K_PAGES || \
473                      IA64_PAGE_SIZE_64KB || MICROBLAZE_64K_PAGES || \
474                      PARISC_PAGE_SIZE_64KB || PPC_64K_PAGES)
475         help
476           This driver supports VMware's vmxnet3 virtual ethernet NIC.
477           To compile this driver as a module, choose M here: the
478           module will be called vmxnet3.
479
480 config FUJITSU_ES
481         tristate "FUJITSU Extended Socket Network Device driver"
482         depends on ACPI
483         help
484           This driver provides support for Extended Socket network device
485           on Extended Partitioning of FUJITSU PRIMEQUEST 2000 E2 series.
486
487 config THUNDERBOLT_NET
488         tristate "Networking over Thunderbolt cable"
489         depends on THUNDERBOLT && INET
490         help
491           Select this if you want to create network between two
492           computers over a Thunderbolt cable. The driver supports Apple
493           ThunderboltIP protocol and allows communication with any host
494           supporting the same protocol including Windows and macOS.
495
496           To compile this driver a module, choose M here. The module will be
497           called thunderbolt-net.
498
499 source "drivers/net/hyperv/Kconfig"
500
501 config NETDEVSIM
502         tristate "Simulated networking device"
503         depends on DEBUG_FS
504         depends on MAY_USE_DEVLINK
505         help
506           This driver is a developer testing tool and software model that can
507           be used to test various control path networking APIs, especially
508           HW-offload related.
509
510           To compile this driver as a module, choose M here: the module
511           will be called netdevsim.
512
513 endif # NETDEVICES