The comm_owned field can hide logic where double locking is attempted
and prevent multiple threads for the same device from accessing the
mutex properly. Remove the comm_owned field and use the mutex API
exclusively for gaining ownership. The current driver has been audited
and is obtaining communications ownership properly.
Signed-off-by: Tom Lendacky <thomas.lendacky@amd.com> Signed-off-by: David S. Miller <davem@davemloft.net>