The formula implementation at armada_get_temp() indicates that the sign
in the formula is inverted.
Cc: Ezequiel Garcia <ezequiel@vanguardiasur.com.ar>
Signed-off-by: Baruch Siach <baruch@tkos.co.il>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
/* Test for a valid sensor value (optional) */
bool (*is_valid)(struct armada_thermal_priv *);
- /* Formula coeficients: temp = (b + m * reg) / div */
+ /* Formula coeficients: temp = (b - m * reg) / div */
unsigned long coef_b;
unsigned long coef_m;
unsigned long coef_div;