From 40fb0eab30ba44bcfc5eb29eb8c78a30025f9e12 Mon Sep 17 00:00:00 2001 From: Sven Eckelmann Date: Fri, 8 Dec 2017 11:37:41 +0100 Subject: [PATCH] dt: bindings: add new dt entry for ath10k calibration variant The bus + bmi-chip-id + bmi-board-id is not enough to identify the correct board data file on QCA4019 based devices. Multiple different boards share the same values. Only the original reference designs can currently be identified and loaded from the board-2.bin. But these will not result in the correct calibration data when combined with the pre-calibration data from the device. An additional "variant" information has to be provided (via SMBIOS or DT) to select the correct board data for a design which was modified by an ODM. Signed-off-by: Sven Eckelmann Signed-off-by: Kalle Valo --- Documentation/devicetree/bindings/net/wireless/qcom,ath10k.txt | 3 +++ 1 file changed, 3 insertions(+) diff --git a/Documentation/devicetree/bindings/net/wireless/qcom,ath10k.txt b/Documentation/devicetree/bindings/net/wireless/qcom,ath10k.txt index 74d7f0af209c..3d2a031217da 100644 --- a/Documentation/devicetree/bindings/net/wireless/qcom,ath10k.txt +++ b/Documentation/devicetree/bindings/net/wireless/qcom,ath10k.txt @@ -41,6 +41,9 @@ Optional properties: - qcom,msi_addr: MSI interrupt address. - qcom,msi_base: Base value to add before writing MSI data into MSI address register. +- qcom,ath10k-calibration-variant: string to search for in the board-2.bin + variant list with the same bus and device + specific ids - qcom,ath10k-calibration-data : calibration data + board specific data as an array, the length can vary between hw versions. -- 2.45.2