From 7f02f18e7f87831747aaa2685f63d16fb2649c6a Mon Sep 17 00:00:00 2001 From: Sekhar Nori Date: Fri, 25 May 2018 13:11:45 -0500 Subject: [PATCH] clk: davinci: pll-dm646x: keep PLL2 SYSCLK1 always enabled PLL2 SYSCLK1 on DM646x is connected to DDR2 PHY and cannot be disabled. Mark it so to prevent unused clock disable infrastructure from disabling it. Signed-off-by: Sekhar Nori Reviewed-by: David Lechner Signed-off-by: Michael Turquette Link: lkml.kernel.org/r/20180525181150.17873-5-david@lechnology.com --- drivers/clk/davinci/pll-dm646x.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/clk/davinci/pll-dm646x.c b/drivers/clk/davinci/pll-dm646x.c index a61cc3256418..0ae827e3ce80 100644 --- a/drivers/clk/davinci/pll-dm646x.c +++ b/drivers/clk/davinci/pll-dm646x.c @@ -72,7 +72,7 @@ static const struct davinci_pll_clk_info dm646x_pll2_info = { .flags = 0, }; -SYSCLK(1, pll2_sysclk1, pll2_pllen, 4, 0); +SYSCLK(1, pll2_sysclk1, pll2_pllen, 4, SYSCLK_ALWAYS_ENABLED); int dm646x_pll2_init(struct device *dev, void __iomem *base) { -- 2.45.2